Sensitive fluorescence sensors as small as sugar cubes

Photo and schematic structure of the compact fluorescence microsensor as OEM component
Source: CiS Forschungsinstitut für Mikrosensorik GmbH.
Jun 11, 2020

Solutions for medical, laboratory and environmental technology

Modern fluorescence sensors should be small, of high resolution and high sensitivity, inexpensive and robust. The CiS Research Institute has met these challenges and developed a technological construction kit for a 2-channel fluorimeter. Such measuring systems are used in medical PoC diagnostics, in the monitoring of diabetes patients, but also in environmental technology for rapid on-site water analysis or in security technology for protection against plagiarism. 

The core components of the fluorimeter include photodiodes with special anti-reflection layers, novel dichroic beam splitters, a powerful bandpass with a high angular acceptance and additional optically direction-selective filters. The quartz glass beam splitter cube, which is only 3x3x3 mm³ in size, contains a novel dichroic layer system consisting of 143 layers of SiO2, Nb2O5 and a mixed material (SixNbyOz) on a diagonally dividing surface, thus realizing an accepted angle of incidence of 45°. Several band-pass filters, which can be manufactured at low cost, ensure optimized interference signal suppression and block unwanted excitation light. Special attention was paid to an improved filter performance for scattered excitation light.

The direction selective filters were manufactured by ICP etching on SOG (Silicon-on-Glass) wafers. So-called "black silicon" was produced on the vertical walls of the resulting cavities. In this way, a transmission of up to 40 % could be achieved at an optical angle of incidence of 0°. At an angle of incidence greater than 13°, the transmission is 0%. Parasitic stray light behind the optical filter can thus be almost completely suppressed.

Microtechnology enables miniaturization in the size of sugar cubes

Microsystem technologies are the basis for the high degree of miniaturization achieved for the entire system, which is no larger than a sugar cube. The holistic system design takes into account optical, electrical and mechanical sub-components at the same time, so that the user not only has a compact sensor module at the end of the process, but also the opportunity of a cost-effective, high-precision and automated assembly. 

The technological construction kit was tested on a demonstrator for measuring the concentration of glucose in aqueous solutions using a fluorescence standard. At an excitation wavelength of 585 nm with an optical power of 160 µW and a sampling rate of 0.5 Hz a detection limit of the measured fluorescence light of approx. 50 pW was achieved. The Stokes shift for the investigations was approx. 35 nm. The research work was funded by the Federal Ministry of Economics and Energy under the funding reference number 27219006.

Contact: Nadin Jurisch, CiS Forschungsinstitut für Mikrosensorik GmbH
njurisch@cismst.de

Member profile

Recommended articles

May 24, 2024

With 20 years of dedication to gas sensing technologies, Cubic, an international manufacturer, has developed diverse mature sensing platforms. Using …

Feb 5, 2025

The SensorNetwork³ Symposium brought together experts from industry, research and politics at the DASA in Dortmund in mid-January to discuss …

Oct 8, 2024

The rapid developments in energy and mobility sectors are driving the need for new solutions. The energy transition and the …

Recommended events

Nov 17 - 20, 2025
Product Market “High-tech for Medical Devices”: A hub for high-tech solutions and medical innovations. Team up with IVAM to pave your way to trade fair success!
Sep 9 - 11, 2026
Manufacturing Processes for Medical Technology
Mar 24 - 26, 2026
Leading European trade fair for autonomous technologies & robotics. Present yourself at the new IVAM joint stand!